Cat No.: BP-310
|
ACE
BP-ACE assay kit is designed to measure Angiotensin-converting enzyme in biological samples without any pretreatment. The improved method forms a colored complex specifically with Angiotensin-converting enzyme . The intensity of the color, measured at 340 nm, is directly proportional to the Angiotensin-converting enzyme in the sample.
Volume 50 ml
|
|
|
Cat No.: BP-311
|
Albumin
BP-Albumin assay kit is designed to measure albumin directly in biological samples. It forms a colored complex specifically with albumin. The intensity of the color, measured at 620nm, is directly proportional to the albumin concentration in the sample.
Volume 500 ml
|
|
|
Cat No.: BP -312
|
AST (SGOT)
BP-AST (SGOT) assaykit activity assay is based on the quantification of oxaloacetate produced by AST. In this assay, oxaloacetate and NADH are converted to malate and NAD by the enzyme malate dehydrogenase. The decrease in NADH absorbance at 340 nm is proportionate to AST activity.
Volume 250 ml
|
|
|
Cat No.: BP -313
|
ALT (SGPT)
BP-ALT (SGPT) assaykit activity assay is based on the quantification of pyruvate produced by ALT. In this assay, pyruvate and NADH are converted to lactate and NAD by the enzyme lactate dehydrogenase (LDH). The decrease in NADH absorbance at 340 nm is proportional to ALT activity.
Volume 250 ml
|
|
|
Cat No.: BP -314
|
Calcium
BP-CALCIUM assaykit is designed to measure calcium directly in biological samples. The intensity of the color, measured at 612 nm, is directly proportional to the calcium concentration in the sample. The optimized formulation minimizes any interference by substances such as magnesium, lipid, protein and bilirubin.
Volume 250 ml
|
|
|
Cat No.: BP -315
|
Cholesterol
BP-CHOLESTROL assaykit uses a single working Reagent that combines cholesterol ester hydrolysis, oxidation and color reaction in one step. The color intensity of the reaction product at 570nm or fluorescence intensity at λex/em = 530/585nm is directly proportional to total cholesterol concentration in the sample.
Volume 500 ml
|
|
|
Cat No.: BP -316
|
CPK
BP-Creatine Kinase Assay Kit is based on enzyme coupled reactions, the glucose-6-phosphate, which is then oxidized by NADP in the presence of glucose-6-phosphate dehydrogenase. The produced NADPH, measured at 340 nm, is proportionate to the CK activity in the sample.
Volume 100 ml
|
|
|
Cat No.: BP -317
|
Creatinine
BP-CREATININE assaykit is designed to measure creatinine directly in biological samples. The intensity of the color, measured at 510nm, is directly proportional to creatinine concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw sample.
Volume 400 ml
|
|
|
Cat No.: BP-318
|
Glucose
BP-Glucose assay kit has now made it possible for the patient to measure his or her own blood glucose concentration and undoubtedly makes the estimation of blood glucose the most widely used test of blood chemistry. An understanding of the methods of blood glucose measurement will help the clinician to interpret values and avoid the pitfalls of inaccurate testing.
Volume 500 ml
|
|
|
Cat No.: BP -319
|
G6PD(qualitative)
Glucose-6-phosphate dehydrogenase (G6PD) qualitative test is used to screen for and help diagnose G6PD deficiencies. A simple qualitative test show if the sample has a certain high level of G6PD.
Volume 50 ml
|
|
|
Cat No.: BP -320
|
G6PD(quantitative)
BP- G6PD assay kit in this kit, glucose-6-phosphate is oxidized to generate a product which is specifically detected by colorimetric (450 nm) assay. The G6PDH Assay Kit can detect G6PDH activity as low as 0.04mU G6PDH per well.
Volume 100 Test
|
|
|
Cat No.: BP -321
|
Iron
BP-IRON assaykit is designed to measure total iron directly in serum without any pretreatment. The improved method utilizes a chromogen that forms a blue colored complex specifically with Fe2+. Fe3+ in the sample is reduced to Fe2+, thus allowing the assay for total iron concentration. The intensity of the color, measured at 590nm, is directly proportional to the iron concentration in the sample.
Volume 250 ml
|
|
|
Cat No.: BP -322
|
LDH
BP-LDH assaykit as a non-radioactive colorimetric LDH assay is based on the reduction of the salt MTT in a NADH-coupled enzymatic reaction to a reduced form of MTT which exhibits an absorption maximum at 565 nm. The intensity of the purple color formed is directly proportional to the enzyme activity.
Volume 250 ml
|
|
|
Cat No.: BP -323
|
Phosphorus
BP- Phosphorus assaydetermins serum inorganic phosphorus concentrations ascomplexofAmmoniummolybdate in the presence of sulphuric acid photometrically in the ultraviolet region (340 nm).
Volume 500 ml
|
|
|
Cat No.: BP -324
|
Urine/CSF (Pyrogallol red)
BP- Urine/CSF determeined Proteins in urine and in cerebral spinal fluid bind pyrogallol red in presence of molybdate and forms a coloured complex in the ultraviolet region (600 nm).
Volume 100 ml
|
|
|
Cat No.: BP -325
|
Bili-Total
BP-BILIRUBIN assaykit is designed to measure bilirubin in blood specimen. The improved Jendrassik-Grof method utilizes the reaction of bilirubin with diazotized sulfanilic acid, in which a red colored product is formed. The intensity of the color, measured at 510-550nm, is an accurate measure of the bilirubin level in the sample. Total bilirubin is assessed using caffeine benzoate to split bilirubin from the unconjugated bilirubin protein complex.
Volume 400 ml
|
|
|
Cat No.: BP -326
|
Bili-Direct
BP-Bili Direct kitkit is designed for the quantitative determination of direct bilirubin in serum. DPD method, measured at 540-560nm
Volume 400 ml
|
|
|
Cat No.: BP -327
|
Direct-TIBC
BP- Direct-TIBC assaykit uses for the determination of total iron-binding capacity in serum on wavelength 660 nm
Volume 100 ml
|
|
|
Cat No.: BP -328
|
Total protein
BP Total proteinassaykit uses for the quantitative determination of total protein concentration in serum on wavelength 546 nm (530-580)
Volume 500 ml
|
|
|
Cat No.: BP -329
|
Triglycerides
BP- Triglyceride assaykit uses a single Working Reagent that combines triglyceride hydrolysis and glycerol determination in one step, in which a dye reagent is oxidized to form a colored product. The color intensity at 570nm is directly proportional to triglyceride concentration in the sample.
Volume 500 ml
|
|
|
Cat No.: BP -330
|
Urea
BP-UREA assaykit is designed to measure urea directly in biological samples without any pretreatment. The improved Jung method utilizes a chromogenic reagent that forms a colored complex specifically with urea. The intensity of the color, measured at 520nm, is directly proportional to the urea concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.
Volume 400 ml
|
|
|
Cat No.: BP -331
|
Uric acid
BP-URIC ACID assaykit is designed to measure uric acid directly in serum without any pretreatment. The improved method forms a blue colored complex specifically with iron in the presence of uric acid. The intensity of the color, measured at 590nm, is directly proportional to the uric acid concentration in the serum. The optimized formulation substantially reduces interference by substances in the raw samples.
Volume 500 ml
|
|
|
Cat No.: BP -332
|
Alk.Phosphatase
BP-Alkaline Phosphatase assaykit is designed to measure ALP activity directly in biological samples without pretreatment. The improved method utilizes p-nitrophenyl phosphate that is hydrolyzed by ALP into a yellow colored product (maximal absorbance at 405nm). The rate of the reaction is directly proportional to the enzyme activity.
Volume 400 ml
|
|
|
Cat No.: BP -333
|
Ammonia
BP-Ammonia assaykit uses for the quantitative determination ofAmonia concentration in serum on wavelength 570 nm
Volume 50 ml
|
|
|
Cat No.: BP -334
|
Chloride
BP-CHLORIDE assaykit is designed to measure chloride directly in biological samples without any pretreatment. The improved Fried method forms a colored complex specifically with chloride. The intensity of the color, measured at 610nm, is directly proportional to the chloride concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.
Volume 100 ml
|
|
|
Cat No.: BP -335
|
Lactate
BP- Lactateassaykit is designed to measure lactate concentration determined by an enzymatic assay, which results in a colorimetric (570 nm), proportional to the lactate present.
Volume 100 ml
|
|
|
Cat No.: BP -336
|
Urine Glucose Strip test
BP- Urine Glucose Strip test detects the presence of glucose (sugar) and in urine. This kit contains 50 test strips.
Volume 50 Test
|
|
|
Cat No.: BP -337
|
Zinc
BP- Zinc assaykit is designed to measure zinc in a variety of samples, including serum, plasma, urine, or cerebral spinal fluid (CSF). Zinc ions bind to a ligand, which results in a colorimetric (560 nm) product proportional to the amount of zinc present
Volume 50 ml
|
|
|
Cat No.: BP-338
|
Copper
BP-Copper assaykit is designed to measurecopper ions. The intensity of the color, measured colorimetrically (359 nm), is directly proportional to copper concentration in the sample.
Volume 50 ml
|
|
|
Cat No.: BP-339
|
Magnesium
BP- Magnesium assaykit is designed to measureMagnesium ion concentration in serum and urine. A colorimetric complex method on wavelength 500 (480-520) nm.
Volume 200 ml
|
|
|
Cat No.: BP-340
|
Ceruloplasmin
BP- Ceruloplasminassaykit is designed to measureceruloplasmin activity in serum. Ceruloplasmin activity is determined using substrate oxidation, which results in a colorimetric (560 nm) product proportional to the enzymatic activity present.
Volume 50 ml
|
|
|
Cat No.: BP-341
|
Calcium (CPC)
BP- Calcium (CPC) assaykit is designed to measuretotal Calcium concentration in serum,plasma or urines. In alkaline solution CPC reacts with calcium to form a
coloured complex which absorbance measured at 570 nm is proportional to the amount of calcium in the specimen.
Volume 250 ml
|
|
|
Cat No.: BP-342
|
TIBC (percipitated)
BP- TIBC (percipitated) assaykit is designed to measure total iron-binding capacity (TIBC), Serumtranferrin is saturated with an excess of Fe3+and the unbound portion is precipitated with magnesium carbonate. The total amount of iron is then determined. The difference between the total iron-binding capacity (TIBC) and initial seric iron(SI) yields the unsatured iron-binding capacity
Volume 100 ml
|
|
|
Cat No.: BP-343
|
HDL-Direct
BP-HDL-Direct kit, serum HDL and LDL/VLDL are first separated and then the cholesterol concentration of each is determined by a coupled enzyme assay, which results in a colorimetric 505 nm product, proportional to the cholesterol present. This kit can also be used to determine the concentration of free cholesterol and cholesteryl esters present in a sample.
Volume 50 ml
|
|
|
Cat No.: BP-344
|
LDL-Direct
BP-LDL-Direct kitassaykit is designed for quantitative measurement of low density lipoprotein cholesterol (LDL-c) in serum and plasma on wavelength 600 nm
Volume 50 ml
|
|
|
Cat No.: BP-398
|
BP-Hitergent
Cleaner solutions compatible for autoanalizer, have stable and reliable quality.
Volume 500 ml
|
|
|
Cat No.: BP-399
|
BP-Multi Clean
Sample cleaner solution for sample probes or reaction cells
on Auto analyzer
Volume 500 ml
|